Turbo Ventilator Solutions

Turbo Ventilators That Cool, Purify, and Ventilate Your Building

Wind-driven industrial roof ventilators that continuously exhaust heat, humidity, fumes, and stale air from factories, warehouses, and commercial buildings with zero electricity, zero running cost, and zero maintenance.

Turbo Ventilators designed for continuous, energy-free air circulation

A turbo ventilator is a wind-driven rooftop ventilation system that continuously removes hot, humid, and contaminated air from a building without electricity. Using natural wind flow and thermal air movement, the rotating turbine creates powerful suction that exhausts indoor heat while drawing in fresh air naturally. Alfaa PEB turbo ventilators are manufactured in high-grade aluminium alloy and stainless steel, available in multiple sizes and base options, and are engineered for reliable performance across all Indian climate conditions.

Zero Electricity. Zero Running Cost. 24/7 Wind & Thermal-Driven Operation Available in 16", 20" & 24" Diameters Aluminium & Stainless Steel Builds
Pre-Engineered Buildings by Alfa PEB Limited

Technical Details

Available Sizes

Turbo Ventilator Available Sizes

01/02

Alfa PEB turbo ventilators are designed for natural roof ventilation in factories, warehouses, industrial sheds, commercial buildings, workshops, and PEB structures. Available in multiple sizes and material options, these wind-driven ventilators help remove hot air, fumes, humidity, and stale air without depending on electricity.

Specification 24 Inch 20 Inch 16 Inch
Available Make Aluminium / Stainless Steel Aluminium / Stainless Steel Aluminium / Stainless Steel
Available Base Aluminium / Stainless Steel Aluminium / Stainless Steel Aluminium / Stainless Steel
Advantages

Advantages of Turbo Ventilators

02/02

Alfa PEB turbo ventilators are designed to provide natural and energy-efficient roof ventilation for factories, warehouses, industrial sheds, workshops, commercial buildings, and PEB structures. Powered by wind energy, these ventilators help remove hot air, fumes, humidity, and stale air without electricity, reducing dependence on exhaust fans and lowering operational costs.

  • Cost-Effective Ventilation: Provides an affordable ventilation solution with low operating cost and no electricity requirement.
  • Suitable for Multiple Building Types: Ideal for factories, warehouses, industrial sheds, workshops, commercial buildings, and PEB structures.
  • 24-Hour Ventilation Support: Helps maintain continuous air movement and improves indoor air circulation throughout the day.
  • Easy Installation: Lightweight design allows quick and simple installation on different roofing systems.
  • Works with Natural Wind Energy: Operates efficiently using wind power and does not require electrical wiring or external power supply.
  • Low Maintenance Performance: Designed with minimal moving parts to reduce maintenance needs and long-term operating expenses.

Applications

Industrial Buildings

Turbo ventilators help remove hot air, fumes, and stale air from industrial buildings, improving natural air circulation and workplace comfort.

Warehouse

Factories & Manufacturing Units

Ideal for factories and production units where continuous roof ventilation is required to reduce heat buildup and improve working conditions.

Industrial shed

Warehouses & Godowns

Suitable for warehouses and godowns to improve airflow, reduce trapped heat, and maintain better storage conditions.

Factory building

PEB Structures

Used in pre-engineered buildings to provide energy-efficient natural ventilation without electrical power or exhaust fans.

Automobile plant

Workshops

Helps ventilate workshops by removing smoke, humidity, and warm air generated during daily operations.

Cold room

Auditoriums & Community Halls

Supports better air movement in large enclosed spaces, reducing heat accumulation and improving indoor comfort.

Aircraft hangar

Hospitals & Schools

Useful for institutional buildings where natural ventilation, fresh air movement, and indoor comfort are important.

Powerhouses & Utility Rooms

Helps remove trapped heat from powerhouses, lift rooms, machine rooms, electrical rooms, and other utility areas.

FAQ's

A turbo ventilator works on two naturally available energy sources wind and thermal buoyancy. Wind passing across the rooftop drives the rotation of the turbine head, which creates a centrifugal suction that continuously draws air upward through the throat and out of the building. Simultaneously, the temperature differential between hot internal air and cooler external air creates a natural convective upflow the thermal stack effect that drives airflow through the ventilator even when wind speed is low. Together, these two forces provide continuous air extraction with no electrical input, no switches, and no operating cost.

Alfaa PEB turbo ventilators are available in 16", 20", and 24" throat diameters, in aluminium or stainless steel, with aluminium or polycarbonate base options. Selecting the right size and number of units depends on your building's floor area, roof height, internal heat load, and local wind conditions. As a general starting point, one correctly sized unit typically covers 50–100 square metres of roof area in standard industrial applications but buildings with high heat loads, chemical processes, or elevated humidity may need higher ventilation rates. Our team will specify your system accurately based on your building parameters.

Yes particularly so. In India's high-temperature industrial climate, the thermal stack effect becomes a primary driver of airflow, meaning turbo ventilators perform strongly even when ambient wind speeds are minimal. The greater the temperature difference between the hot internal air and the outside ambient, the stronger the natural convective pull through the ventilator. This makes them especially effective in Indian warehouse and factory conditions, where internal temperatures during summer months can significantly exceed outdoor ambient levels.

Properly specified and installed turbo ventilators require virtually no routine maintenance. Alfaa PEB units use sealed, self-lubricating bearing assemblies no periodic greasing, no lubrication schedule, no service visits required. A visual inspection of the base flashing seal and a check for unobstructed blade rotation once or twice a year is the full recommended maintenance regime. No electrical components, no motors, no filters, no consumables nothing to power, replace, or service on any regular basis.

Yes. Turbo ventilators can be installed on existing metal sheet roofs, asbestos-cement roofs, and concrete roofs as well as being integrated during new PEB construction. For existing roofs, installation involves cutting a correctly sized penetration, fitting the appropriate base flashing with a collar seal matched to your roof sheet profile, and securing and aligning the turbine head. Our team can assess retrofit feasibility for your existing roof and confirm the correct base flashing type for your specific roofing material and pitch.

Ready to Build? Let’s Plan Your Next Facility

Share your requirements and our team will deliver the right PEB solution from concept and engineering to execution.

Request a Quote
Chat on WhatsApp Call Us Now